 Коды ошибок:

Системные ошибки
E198 - Flash ROM write error (ошибка записи ROM)
E674 - Modem error (ошибка модема)

Ошибка сканера
E225 - CIS lamp has a fault (неисправность лампы CIS)

Ошибки принтера
E000 - The High-voltage PCB has a fault (неисправность платы PCB)
E100 - The scanner assembly has a fault (неисправность узла сканера)

Коммуникационные ошибки
0001 - Nothing G3 signal received within 35 sec (потеря сигнала G3 в течение 35 секунд)
0003 - Received DIS after sending DIS signal
0004 - Received DCN after sending DTC signal
0009 - Can't receive any signal within 35 sec. in manual polling mode (невозможно принять сигнал в течение 35 секунд в ручном режиме)
0010 - Received DCN signal after sending DTC signal in Polling Rx
0011 - Can't receive any correct response after sending DTC signal (невозможно принять правильный ответ после отправки сигнала DTC)
0012 - Remote side Password not match in Polling Rx/our side no any file to be polling
0013 - Can't receive carrier within 6 sec. after sending CFR in date phase C
0014 - Can't receive T.30 signal after sending FTT signal (невозможно принять сигнал T.30)
0016 - Receive DCN signal after sending PTT signal
0017 - Can't receive any response from remote side after sending DIS
0018 - Can't detect energy within 6 sec after sending FTT command
0019 - Received DCN signal sending CFR signal
001A - No energy on line over 6 sec. within phase C before any corrected ECM frame
001D - Can't detect flag after sending CFR signal
001E - Timeout in V.17 ECM Rx phase C
0020 - Can't correct frame within 6 sec at phase C
0021 - File full.
0022 - Owing to noise interference on the line, receiving side can't receive correct data within specified time (no ECM)
0023 - Can't receive correct signal after sending CFR signal
0030 - Can't receive any signal within 6 sec. At phase D
0031 - Received incorrect signal at phase D (not EOP, MPS, EOM, DCN, PPS_Q, PPS_Q,etc)
0032 - Can't receive carrier within 6 sec after sending MCF or RTP, RTN signal
0033 - Received DCN signal at ohase D within pages (not last page)
0039 - In non_ECM mode, when machine alredy received the data dosen't receive 13.1 seconds
001F - Can't detect any G3 signal within 35 sec after sending DTC signal
003F - Remote side TSI not define in machine one touch or speed dial directory
0040 - Can't receive carrier within 6 sec. after sending CTR
0041 - Can't receive carrier within 6 sec. after sending PPR
0042 - Can't receive correct signal after sending RNR signal
0043 - Receive incorrect signal at phase D in ECM mode
0044 - Can't receive carrier/FSK signal within 6 sec. After sending MCF. ln ECM mode.
0047 - Can't receive correct signal or DCN received after sending ERR signal.
0048 - Can't receive correct signal after receive PPS_PRI_Q
004B - Can't detect correct FSK signal even through detected FSK tone within 6 sec.
004C - Handshake fail during re-train or between page in V34 Rx
004E - Receive DCN signal after sending DIS in V.34
004F - Remote side disconnected after sending ANSam in V.8 phase
0050 - Can't receive any correct signal after detected CJ signal in V.8 phase
0051 - Can't receive phase 3 signal after phase 2 within 20 seconds in V.34
0053 - Modem disconnect after phase 4 in V.34
0054 - Remote side disconnect after phase 4 in V.8
0055 - Receive incorrect signal after sending DIS signal in V.34
0056 - Modem disconnect after sending CFR in V.34
0058 - Can't detect image signal within 6 sec after modem enter to primary phase in V.34
005A - Modem cannot detect any correct ECM frame with 3 minutes in phase C
005B - Modem can't detect control channel with 12 sec in phase C
005C - Detect busy tone within control channel after phase C
005D - Modem can't detect any correct ECM frame with 12 sec in phase C
005E - Can't detect control channel signal after received RCP frame within 6 sec
005F - Can't detect silence after sending JM signal for polling TX function
0060 - There are no any bullietin files to be polled in V.34
0061 - Machine cannot detect V.21 or V.8 signal with 35 sec
0062 - Modem disconnect in phase D after our side sending out flags sequence in control channel
0063 - Can't receive any flag sequence in control channel within 25 sec in phase D
0064 - Can't detect any control channel signal in phase D within 60 sec even through energy still on the line
0065 - Can't detect any control channel signal within 60 sec after detect sillence in phase D
0066 - Can't receive T.30 signal or carrier after sending CFR in V.34
0069 - Capability no match paper size after received is DCS signal
0070 - User press stop key within receiving
0071 - Memory full within receiving
0080 - Can't detect any G3 signal within 35 sec. specified by ITU-T in phase B
0081 - Received DTC signal in transmission phase
0082 - Transmitting unit receives a signal other than DIS or DTC. And DCN in phase B
0083 - Detected FSK signal, but Can't receive any signal within 35 sec
0084 - Detect DCN signal in phase B
0085 - Transmitting unit sending DCS 3 times consecutively, but each time responds with DIS/DTC
0086 - Detected responds signal other than DTC,DIS,FTT,DCN or CFR after sending DCS
0087 - Training attempt has failed because speed unit can't adjust to low lower speed
0088 - Received DCN signal after sending out DCS signal
008B - Receivers protcol of DIS is received, but it is not compatible with our machine
008C - Remote side or our side not support capability
008D - Receivers protocol of DIS is received, but remote side can't receive document temporary, may because by run out of paper or other reason
008F - Modem not ready to received V.34 data within 6 sec after received CFR signal
0090 - Called side document not ready for our polling
0091 - Can't receive any commabd after send DCN signal 3 times consecutively
0093 - Received DCN signal after sending out DCN signal
0094 - Time out during transmit ECM frame or RCP command
0095 - Wrong ID number
0096 - SUBADDRESS/PASSWORD capability not match in polling Rx mode
009A - Can't detect any signal after sending CI signal.
009D - Remote side hang up before V.34 modem enter phase 2 state in V.34 polling Rx
009E - Manual Tx over 15 minutes whin in phase C by non-ECM mode
00A0 - User stop or cancel transmission job
00A1 - Document JAM within transmission
00AE - Can't finished V.8 procedure or detect V.21 signal after CM signal
00AF - Modem can't enter into control channel after TX side sending out RCP signal
for V34
00B1 - Can't finish V.8 procedure or detect V.21 signal after ANSam signal within 35 sec
00B2 - Can't detect phase 2 signal after our side sending CJ signal within 30 sec
00B3 - Can't detect correct V.21 or JM signal after sending CM or CJ signal
00B4 - Can't detect correct phase 2 signal within 25 second after CM/JM signal exchange
00B5 - Can't detect phase 3 signal after Phase 2
00B6 - Can't detect phase 4 signal within 25 sec after CM/JM exchange
00B8 - Remote side disconnect after our side sending DCS signal in V.34
00BA - Cannot received correct signal after our side sending DTC signal in V.34
00BB - Every time our side received DIS signal after sending DTC in V.34
00BC - Modem can't ready within 10 second after entering primary channel in V.34
00BD - Can't detect correct V.21 or JM signal after detected FSK frequency
00BE - Remote side no document to be polled after V.8 handshaking
00BF - Capability no match after V.8 handshaking
00C1 - At phase-D, transmitting units out EOP 3 times consecutively, but receive no answer from receiving unit
00C2 - Remote side disconnect after sending out V.8 CM signal
00C4 - After sending MPS signal, the received is not one of MCF, RTN, PIP, PIN, RTP, DCN
00C5 - Received DCN signal after sending MPS signal
00C9 - At phase D, sending MPS 3 times consecutively, but no answer from receiveing unit
00CA - After sending EOP signal, the received is not one of MCF, RTN, PIP, PIN, PRI-EOP, DCN, RTP.
00CB - After sending EOP signal, the received is DCN signal
00CF - Received incorrect signal after sending DTC signal for V.34 polling
00D0 - Received ERR signal after sending EOR_NULL
00D1 - Received incorrect response after sending PPS_EOP signal
00D2 - Received DCN after sending PPS_EOP signal
00D3 - Received DCN after sending PPS_NULL signal
00D8 - Can't detect correct phase 3 signal for poling
00D9 - Can't detect correct phase 3 signal after detect silence after phase 2
00DA - Can't detect phase 4 signal within 30 sec
00DB - Can't received any T.30 signal within 30 sec within phase 4
00DC - Received T.30 signal in phase 4 other than DCS, DIS or DTC
00DE - Remote side no SUB capability
00E0 - At phase-D, transmitting units out PPS_NULL 3 times consecutively but receive not answer
00E1 - Received incorrect response after sending PPS_NULL
00E2 - Can't receive any response in RR response procedure after sending PPS_NULL
00E4 - At phase D, transmitting units out PPS_MPS 3 times consecutivery but receive no answer
00E5 - Received incorrect response after sending PPS_MPS signal
00E6 - Can't receive any response in RR response procedure after sending PPS_MPS
00E7 - Reseived DCN after sending PPS_MPS
00E8 - At phase-D, transmitting units out PPS_EOP 3 times consecutively but receive no answer
00E9 - Receive PIN signal after sent last page data
00EA - Can't receive any response in RR response procedure after sending PPS_EOP
00EE - At phase-D, transmitting units out EOR_NULL 3 times consecutively but receive no answer
00EF - Received incorrect response after sending EOR_NULL
00F0 - Can't receive any response in RR response procedure after sending EOR_NULL
00F1 - At phasa-D, transmitting units out EOR_MPS 3 times consecutively but receive no answer
00F2 - Received incorrect response after sending EOR_MPS
00F3 - Received ERR signal after sending EOR_MPS
00F4 - Can't receive any response in RR response procedure after sending EOR_MPS
00F5 - At phasa-D, transmitting units out EOR_EOP 3 times consecutively but receive no answer
00F6 - Received incorrect response after sending EOR_EOP
00F7 - After Received ERR, our side can't received response after sending EOR_EOP command
00FC - Can't receive any response after sending CTC
00FD - Can't speed down to lower speed
00FE - Memory full for transmission
00FF - REDAIL ALL FAIL